Overview
The SN-58B is a hand crimping tool for building your own connector leads. It forms small open-barrel terminals around a stripped wire: one squeeze folds the terminal’s front wings into the bare conductor and its rear wings around the insulation. The supplier lists this orange-and-black tool for two terminal families — Dupont-style 2.54 mm and XH2.54 — which together cover most jumper leads and many small board connectors.
Custom leads change how a project goes together. Instead of a bundle of mismatched jumpers, you get cables cut to length, with the right connector on each end and the wires in the right order — the difference between a prototype and something that survives being moved.
This listing does not publish a wire range or die dimensions, and ratings from another maker’s SN-58B should not be assumed to apply. Other SN-58B tools are commonly specified for 0.25–1.5 mm² wire (AWG 24–16), which hints that very thin jumper wire may need extra care. The reliable approach is the one professionals use: make a test crimp with your exact wire and terminal, inspect it, and pull on it before building the real cable.
At a Glance
Specifications
| Parameter | Value |
| Model | SN-58B |
| Tool type | Hand-operated terminal crimping pliers |
| Supplier-listed terminals | Dupont-style 2.54 mm and XH2.54 |
| Terminal style | Open-barrel contacts with separate conductor and insulation wings |
| Wire range | Not published for this tool |
| Reference only | Other makers’ SN-58B tools are commonly specified for 0.25–1.5 mm² (AWG 24–16) — do not assume the same here |
| Die dimensions and crimp height | Not published |
| Handles | Orange and black |
| In the box | 1 crimping tool |
| Not included | Terminals, housings, and wire |
How to Use
A good crimp is repeatable, so settle the method on scrap first. Match the terminal to the wire, choose the die cavity that just fits the terminal, and prove the result with a pull test before you build a cable you care about. Terminals and housings are sold separately — for example in the 620-piece Dupont-style kit.
Crimping a Dupont-Style Terminal
| Step | What To Do | Notes |
|---|---|---|
| 1. Strip | Remove about 2–3 mm of insulation | Bare wire should fill the front wings without poking into the mating end |
| 2. Seat the terminal | Place it in the smallest die cavity it fits, wings facing the curved side of the die | The mating end stays outside the jaws so it is not crushed |
| 3. Hold it | Close the handles just enough to grip the terminal | If your tool has a ratchet, one or two clicks hold it for you |
| 4. Insert the wire | Bare strands under the front wings, insulation under the rear wings | The insulation should end between the two sets of wings |
| 5. Crimp | Squeeze fully until the tool releases | A ratchet tool will not reopen until the stroke is complete |
| 6. Fit the housing | Push the terminal into the housing until it clicks | The small locking tab faces the housing’s window |
Crimping an XH2.54 Terminal
XH-style terminals are smaller than Dupont terminals and lock into a shrouded housing, but the method is the same.
| Step | What To Do | Notes |
|---|---|---|
| 1. Strip | Remove about 2 mm of insulation | These contacts have short conductor wings |
| 2. Seat the terminal | Use the smallest cavity that accepts it, wings toward the curved side | Keep the contact end clear of the jaws |
| 3. Insert and crimp | Strands under the front wings, insulation under the rear wings, then squeeze fully | Check that no strands escaped the wings |
| 4. Fit the housing | Insert with the terminal’s locking barb toward the housing’s slot until it clicks | Tug the wire gently to confirm it has latched |
Checking a Crimp
| Check | Good | Bad |
|---|---|---|
| Conductor crimp | Front wings rolled in tightly, strands just visible at the front | Loose strands outside the wings, or the wire slides when pulled |
| Insulation crimp | Rear wings hug the insulation without cutting it | Wings pierce the insulation, or grip bare wire only |
| Shape | Terminal stays straight | A bent or twisted terminal that will not enter the housing |
| Pull test | A firm tug does not move the wire | The wire pulls out — re-crimp with a new terminal |
| Housing fit | Clicks in and stays when the wire is tugged | Slides back out, or needs force to insert |
Troubleshooting
| Problem | Likely Cause | Fix |
|---|---|---|
| Wire pulls out | Cavity too large for the terminal, or wire too thin | Use a smaller cavity; double thin wire by folding the stripped end |
| Terminal is crushed or will not fit the housing | Cavity too small, or the mating end was inside the jaws | Move up one cavity and keep the mating end outside the die |
| Insulation wings cut into the wire | The wire sat too far forward | Re-strip so the insulation ends between the two sets of wings |
| Terminal twists while crimping | It was not seated squarely | Grip it lightly first, straighten it, then insert the wire |
| Handles will not reopen | The ratchet has not completed its stroke | Finish the squeeze, or use the release lever if your tool has one |